HomeKnowledgePVC Pipe — Schedule 40
🧱 Materialmaterialsplumbing

PVC Pipe — Schedule 40

Updated Mar 25, 2026
Standard white PVC drain/waste/vent pipe. Most common DWV pipe in residential construction.

Schedule 40 PVC: ASTM D2665 (DWV), ASTM D1785 (pressure). White color. Sizes: 1-1/2 in through 6 in for DWV. Wall thickness: 2 in = 0.154 in, 3 in = 0.216 in, 4 in = 0.237 in. Max operating temp: 140°F (not for hot water supply). DWV uses: waste, vent, drain lines. Joining: solvent cement (primer required by code in most jurisdictions). Cannot be used above ground where exposed to sunlight (UV degradation) without painting or sleeving. Cost: $0.50-$4/ft depending on diameter. Advantages: lightweight, chemical resistant, easy to cut/join, low cost. Fire rating: limited — releases HCl when burned, must be firestopped at rated assemblies. CSI 22 13 16. Cannot be used for compressed air or flammable fluids.

TAGS
PVCpipeplumbingDWVdrainvent
DETAILS
sizes
["1-1/2","2","3","4","6"]
max temp
140°F
standard
ASTM D2665
cost per ft
$0.50-$4
csi division
22 13 16
sustainability grade
D
RELATED KNOWLEDGE
🧱 Material
Concrete — 4,000 PSI Normal Weight
Standard structural concrete mix with 4,000 psi compressive strength at 28 days, 150 pcf unit weight. Most common mix for foundations, slabs, columns, and beams in commercial and residential construction.
🧱 Material
Structural Steel — ASTM A992 (W-shapes)
Standard structural steel for wide-flange shapes (W-beams, W-columns). 50 ksi yield strength, 65 ksi tensile strength. The dominant steel grade for structural framing in commercial construction.
🧱 Material
Lumber — SPF 2x4 Stud Grade (Spruce-Pine-Fir)
Standard dimensional lumber for wall framing. Actual dimensions 1.5 x 3.5 inches. Available in 8, 10, 12, 16 foot lengths. Stud grade meets IBC requirements for bearing walls up to 10 feet.
🧱 Material
Romex NM-B 12/2 — Non-Metallic Sheathed Cable (Residential Wiring)
Standard residential electrical wiring: 12 AWG copper, 2 conductors + ground, NM-B rated. For 20-amp circuits. Used for kitchen, bathroom, laundry, garage receptacles per NEC. Interior dry locations only.
🧱 Material
Gypsum Board — 5/8" Type X (Fire-Rated)
Fire-rated gypsum wallboard providing 1-hour fire resistance when applied to each side of a wood or steel stud wall. Required by IBC for fire-resistance-rated assemblies. 4x8 and 4x12 sheets standard.
🧱 Material
Reinforcing Steel — Grade 60 Deformed Bar (#4 through #11)
Standard reinforcing steel for concrete construction. 60,000 psi yield strength. Deformed surface for bond with concrete. Used in foundations, slabs, columns, beams, and walls. Specified per ACI 318.
← Back to Knowledge Garden