CEC / NEC 210.52(C) — Kitchen Counter Receptacles (post-2023 change)

Updated May 18, 2026
CEC adopts NEC 2023: 210.52(C)(2) for islands/peninsulas was DELETED — no longer requires receptacles on island faces.

California Electrical Code (Title 24 Part 3) adopts NEC 2023. Important rule change: 210.52(C)(2) — the requirement for receptacles on kitchen islands and peninsulas was ELIMINATED in NEC 2023 due to safety concerns (cord-on-floor hazard, kitchen-fire causation). Existing islands may keep their receptacles. New construction: no island-face receptacle required, but counter receptacles every 24 inches along walls per 210.52(C)(1) still apply, GFCI per 210.8(A) for all kitchen receptacles within 6 ft of sink. AZ and NV still on NEC 2020 (or earlier) — old 210.52(C)(5) island-receptacle rule still applies there.

TAGS
kitchenrenoreceptacleNECGFCIsuperseded
DETAILS
edition
2023
use case
["residential-reno","kitchen","small-jobs"]
adopted by
["ca-statewide","ca-marin","ca-sf","ca-oakland","ca-san-jose"]
code system
NEC/CEC
confidence tier
primary
SOURCES
🔗https://codes.iccsafe.org/codes/california/CAEC2022P1
RELATED KNOWLEDGE
📋 Code
IMC Chapter 6 — Duct Systems
Duct materials, SMACNA construction, fire/smoke dampers, flex duct, plenum requirements.
📋 Code
IMC Chapter 10 — Boilers, Water Heaters, Pressure Vessels
Boiler rooms, clearances, T&P relief valves, expansion tanks, combustion air requirements.
📋 Code
IMC Chapter 5: Exhaust Systems
Technical requirements for imc chapter 5: exhaust systems.
📋 Code
IMC Chapter 6: Duct Systems
Technical requirements for imc chapter 6: duct systems.
📋 Code
IMC Chapter 7: Combustion Air
Technical requirements for imc chapter 7: combustion air.
📋 Code
IMC Chapter 8: Chimneys and Vents
Technical requirements for imc chapter 8: chimneys and vents.
← Back to Knowledge Garden