📋 Codecodesfire

CRC R327 — Marin Wildland-Urban Interface

Updated May 18, 2026
Ignition-resistant exterior construction mandatory in Marin WUI zones; Class A roof, non-combustible siding, ember-resistant vents.

CRC Chapter 7A / R327 governs construction in California State Responsibility Areas (SRA) and Marin Local Responsibility Areas (LRA-VHFHSZ). Most of Marin County is mapped as Very High Fire Hazard Severity Zone. Requirements: Class A roof assembly, non-combustible or ignition-resistant siding, dual-pane tempered glazing within 10 ft of grade, 1/8 inch mesh ember-resistant vents, fully enclosed eaves. Defensible space (PRC 4291) extends 100 ft.

TAGS
marinWUIwildfireChapter-7Adefensible-space
DETAILS
edition
2022
adopted by
["ca-marin","ca-marin-county"]
code system
CRC
confidence tier
primary
jurisdiction label
Marin County, CA
SOURCES
🔗https://codes.iccsafe.org/codes/california/CARC2022P1
RELATED KNOWLEDGE
📋 Code
IMC Chapter 6 — Duct Systems
Duct materials, SMACNA construction, fire/smoke dampers, flex duct, plenum requirements.
📋 Code
IMC Chapter 10 — Boilers, Water Heaters, Pressure Vessels
Boiler rooms, clearances, T&P relief valves, expansion tanks, combustion air requirements.
📋 Code
IMC Chapter 5: Exhaust Systems
Technical requirements for imc chapter 5: exhaust systems.
📋 Code
IMC Chapter 6: Duct Systems
Technical requirements for imc chapter 6: duct systems.
📋 Code
IMC Chapter 7: Combustion Air
Technical requirements for imc chapter 7: combustion air.
📋 Code
IMC Chapter 8: Chimneys and Vents
Technical requirements for imc chapter 8: chimneys and vents.
← Back to Knowledge Garden