IBC 2113 — Masonry Fireplaces and Chimneys

Updated Mar 25, 2026
Masonry fireplaces require: firebox minimum 20 inches deep, firebrick lining, 2-inch clearance to combustibles, cricket/saddle flashing for chimneys wider than 30 inches. Seismic reinforcement required in SDC D/E/F.

Masonry fireplace and chimney requirements per IBC 2113 and IRC R1003. Firebox: minimum 20 inches deep. Lining: firebrick minimum 2 inches thick laid in refractory mortar. Throat: minimum 8 inches above firebox, damper full width. Flue: clay flue liner (ASTM C315) or stainless steel liner. Size per Table R1003.1 based on fireplace opening. Chimney: minimum 3-5/8 inch nominal brick with flue liner, OR reinforced concrete minimum 4 inches. Height: minimum 3 feet above roof penetration, 2 feet above anything within 10 feet horizontally. Clearance to combustibles: minimum 2 inches all sides. Cricket/saddle: required on upslope side when chimney is wider than 30 inches. Spark arrestor: required in many jurisdictions (especially wildfire zones). Seismic: in SDC D/E/F, chimney must be reinforced with minimum 4 #4 vertical bars and #3 horizontal ties at 18-inch intervals, fully grouted.

TAGS
fireplacechimneymasonryfirebrickflueibcircresidential
DETAILS
chapter
21 - Masonry
severity
life_safety
code year
2024
code system
IBC
building types
["residential_single","residential_multi"]
section number
2113
RELATED KNOWLEDGE
📋 Code
IBC 903.2.1 — Group A Occupancies (Sprinkler Requirements)
Automatic sprinkler system required throughout buildings with Group A occupancy where fire area exceeds 5,000 square feet, or overall building area exceeds 12,000 square feet, or occupant load of the fire area exceeds 300.
📋 Code
IBC 903.2.7 — Group M Occupancies (Retail Sprinkler Requirements)
Automatic sprinkler system required in Group M (mercantile) occupancies where fire area exceeds 12,000 square feet or building is more than three stories above grade.
📋 Code
IBC 903.2.11.3 — Buildings 55 Feet or More in Height
Automatic sprinkler system required throughout buildings with a floor level having an occupant load of 30 or more that is located 55 feet or more above the lowest level of fire department vehicle access.
📋 Code
IBC 1015.1 — Exit and Exit Access Doorways Required
Two exits or exit access doorways required from any space where occupant load exceeds the table values. Spaces with occupant load exceeding 500 require a minimum of 3 exits. Spaces exceeding 1,000 require 4 exits.
📋 Code
IBC 1017.2 — Exit Access Travel Distance
Maximum travel distance from any point in a building to an exit shall not exceed 200 feet unsprinklered or 250 feet sprinklered for most occupancies. Specific occupancies have modified limits.
📋 Code
IBC Table 601 — Fire-Resistance Rating Requirements
Specifies minimum fire-resistance ratings for structural elements based on construction type (Type I through V). Type IA requires 3-hour rated structural frame, 2-hour floors, and 1.5-hour roof.
← Back to Knowledge Garden