IBC Chapter 18 — Soils and Foundations

Updated Mar 25, 2026
Geotechnical requirements, soil bearing capacity, deep foundations, ground improvement.

Section 1803: Geotechnical investigations required for: buildings >1 story, retaining >4ft, piles/piers, structures on potentially problematic soils. Report includes: soil classification, bearing capacity, settlement analysis, lateral pressures, groundwater. Section 1804: Excavation/grading/fills — fill placement in max 12in lifts, compacted per geotech recommendations. Section 1806: Foundation design: presumptive bearing values (Table 1806.2): crystalline bedrock 12,000 psf, sedimentary 4,000, sandy gravel 3,000, sand 2,000, clay 1,500. Or per geotech report. Section 1808: Footings — depth below frost line, min 12in below adjacent grade. On stable undisturbed soil or compacted fill. Section 1810: Deep foundations — piles: driven, drilled, helical, micropile. Minimum 2 test piles per building. Load test per ASTM D1143. Section 1807: Foundation walls — damp-proofing required, waterproofing for habitable below-grade spaces.

TAGS
IBCfoundationsgeotechnicalsoilbearing-capacitypiles
DETAILS
code year
2024
code system
IBC
code section
Chapter 18
RELATED KNOWLEDGE
📋 Code
IBC 903.2.1 — Group A Occupancies (Sprinkler Requirements)
Automatic sprinkler system required throughout buildings with Group A occupancy where fire area exceeds 5,000 square feet, or overall building area exceeds 12,000 square feet, or occupant load of the fire area exceeds 300.
📋 Code
IBC 903.2.7 — Group M Occupancies (Retail Sprinkler Requirements)
Automatic sprinkler system required in Group M (mercantile) occupancies where fire area exceeds 12,000 square feet or building is more than three stories above grade.
📋 Code
IBC 903.2.11.3 — Buildings 55 Feet or More in Height
Automatic sprinkler system required throughout buildings with a floor level having an occupant load of 30 or more that is located 55 feet or more above the lowest level of fire department vehicle access.
📋 Code
IBC 1015.1 — Exit and Exit Access Doorways Required
Two exits or exit access doorways required from any space where occupant load exceeds the table values. Spaces with occupant load exceeding 500 require a minimum of 3 exits. Spaces exceeding 1,000 require 4 exits.
📋 Code
IBC 1017.2 — Exit Access Travel Distance
Maximum travel distance from any point in a building to an exit shall not exceed 200 feet unsprinklered or 250 feet sprinklered for most occupancies. Specific occupancies have modified limits.
📋 Code
IBC Table 601 — Fire-Resistance Rating Requirements
Specifies minimum fire-resistance ratings for structural elements based on construction type (Type I through V). Type IA requires 3-hour rated structural frame, 2-hour floors, and 1.5-hour roof.
← Back to Knowledge Garden