IBC Chapter 21 — Masonry

Updated Mar 25, 2026
Masonry construction design and materials referencing TMS 402/602 for structural masonry.

IBC Ch21: structural masonry per TMS 402/602. Section 2101 — masonry units: concrete (ASTM C90), clay (ASTM C62/C216), AAC (ASTM C1693). Mortar: ASTM C270 (Types M, S, N, O). Grout: ASTM C476 (minimum 2,000 psi). Section 2106 — special inspections: Level 1 (periodic) or Level 2 (continuous) per IBC 1705.4. Required for all engineered masonry and empirical masonry in SDC D+. Section 2107 — ASD per TMS 402 Chapter 8. Section 2108 — strength design per TMS 402 Chapter 9. Section 2109 — empirical design (limited to 35 ft, non-seismic). Section 2110 — glass unit masonry (glass block). Section 2104 — construction: cold weather protection (maintain 40F for 24 hrs), hot weather (wet units, shade mortar).

TAGS
IBCmasonryTMS-402CMUbrickstructural
DETAILS
code year
2024
code section
Chapter 21
RELATED KNOWLEDGE
📋 Code
IBC 903.2.1 — Group A Occupancies (Sprinkler Requirements)
Automatic sprinkler system required throughout buildings with Group A occupancy where fire area exceeds 5,000 square feet, or overall building area exceeds 12,000 square feet, or occupant load of the fire area exceeds 300.
📋 Code
IBC 903.2.7 — Group M Occupancies (Retail Sprinkler Requirements)
Automatic sprinkler system required in Group M (mercantile) occupancies where fire area exceeds 12,000 square feet or building is more than three stories above grade.
📋 Code
IBC 903.2.11.3 — Buildings 55 Feet or More in Height
Automatic sprinkler system required throughout buildings with a floor level having an occupant load of 30 or more that is located 55 feet or more above the lowest level of fire department vehicle access.
📋 Code
IBC 1015.1 — Exit and Exit Access Doorways Required
Two exits or exit access doorways required from any space where occupant load exceeds the table values. Spaces with occupant load exceeding 500 require a minimum of 3 exits. Spaces exceeding 1,000 require 4 exits.
📋 Code
IBC 1017.2 — Exit Access Travel Distance
Maximum travel distance from any point in a building to an exit shall not exceed 200 feet unsprinklered or 250 feet sprinklered for most occupancies. Specific occupancies have modified limits.
📋 Code
IBC Table 601 — Fire-Resistance Rating Requirements
Specifies minimum fire-resistance ratings for structural elements based on construction type (Type I through V). Type IA requires 3-hour rated structural frame, 2-hour floors, and 1.5-hour roof.