IBC Chapter 24 — Glass and Glazing

Updated Mar 26, 2026
Glass types, safety glazing, structural glazing, sloped glazing, and impact-resistant glazing requirements.

IBC Ch24: 2405 safety glazing per CPSC 16 CFR 1201. Required in: doors, shower/tub enclosures, guards/railings, within 24in of door (impact zone), panels >9sf with bottom edge <18in. Tempered: 4x strength of annealed, breaks into small pieces. Laminated: holds together when broken, impact-resistant. IGU: insulated glass unit, 2-3 panes with sealed airspace. Low-e: metallic coating reduces solar heat gain. Chapter references ASTM E1300 for wind load resistance, ASCE 7 for load determination. Sloped glazing (>15 degrees from vertical): laminated or screened below per 2405.3. HVHZ: impact-rated per ASTM E1886/E1996 or missile-impact testing.

TAGS
IBCglassglazingsafety-glazingtemperedlaminated
DETAILS
code year
2024
code section
Chapter 24
RELATED KNOWLEDGE
📋 Code
IBC 903.2.1 — Group A Occupancies (Sprinkler Requirements)
Automatic sprinkler system required throughout buildings with Group A occupancy where fire area exceeds 5,000 square feet, or overall building area exceeds 12,000 square feet, or occupant load of the fire area exceeds 300.
📋 Code
IBC 903.2.7 — Group M Occupancies (Retail Sprinkler Requirements)
Automatic sprinkler system required in Group M (mercantile) occupancies where fire area exceeds 12,000 square feet or building is more than three stories above grade.
📋 Code
IBC 903.2.11.3 — Buildings 55 Feet or More in Height
Automatic sprinkler system required throughout buildings with a floor level having an occupant load of 30 or more that is located 55 feet or more above the lowest level of fire department vehicle access.
📋 Code
IBC 1015.1 — Exit and Exit Access Doorways Required
Two exits or exit access doorways required from any space where occupant load exceeds the table values. Spaces with occupant load exceeding 500 require a minimum of 3 exits. Spaces exceeding 1,000 require 4 exits.
📋 Code
IBC 1017.2 — Exit Access Travel Distance
Maximum travel distance from any point in a building to an exit shall not exceed 200 feet unsprinklered or 250 feet sprinklered for most occupancies. Specific occupancies have modified limits.
📋 Code
IBC Table 601 — Fire-Resistance Rating Requirements
Specifies minimum fire-resistance ratings for structural elements based on construction type (Type I through V). Type IA requires 3-hour rated structural frame, 2-hour floors, and 1.5-hour roof.