IRC R302 — Fire-Resistant Construction

Updated Mar 25, 2026
Residential fire-safety requirements including fire-resistance ratings for townhouse separation walls, dwelling unit separation, and garage separation.

Section R302.1: Exterior walls — fire separation distance <3 ft: 1-hr rated with 0% openings. 3-5 ft: 1-hr rated with 25% openings. ≥5 ft: no rating, unlimited openings. Projections within 2 ft of property line limited. Section R302.2: Townhouse separation — 1-hr common wall (each side rated independently) or 2-hr common wall (tested as assembly). Through-penetration protection. Section R302.3: Two-family dwellings — 1-hr separation between units. Section R302.5: Dwelling-garage separation — 1/2-hr gypsum (5/8 Type X) on garage side of common walls. Self-closing door (20-min rated). No openings from garage to sleeping rooms. Section R302.6: Dwelling-garage fire sprinklers — IRC P2904 sprinkler system permits reduction of garage separation. Section R302.7: Under-stair protection — enclosed space under stairs protected with 1/2 in gypsum. Section R302.11: Fireblocking — required at ceiling/floor levels, soffits, stair stringers, 10 ft intervals in concealed spaces.

TAGS
IRCresidentialfire-safetygarage-separationtownhousefireblocking
DETAILS
code year
2024
code system
IRC
code section
R302
RELATED KNOWLEDGE
📋 Code
IBC 903.2.1 — Group A Occupancies (Sprinkler Requirements)
Automatic sprinkler system required throughout buildings with Group A occupancy where fire area exceeds 5,000 square feet, or overall building area exceeds 12,000 square feet, or occupant load of the fire area exceeds 300.
📋 Code
IBC 903.2.7 — Group M Occupancies (Retail Sprinkler Requirements)
Automatic sprinkler system required in Group M (mercantile) occupancies where fire area exceeds 12,000 square feet or building is more than three stories above grade.
📋 Code
IBC 903.2.11.3 — Buildings 55 Feet or More in Height
Automatic sprinkler system required throughout buildings with a floor level having an occupant load of 30 or more that is located 55 feet or more above the lowest level of fire department vehicle access.
📋 Code
IBC 1015.1 — Exit and Exit Access Doorways Required
Two exits or exit access doorways required from any space where occupant load exceeds the table values. Spaces with occupant load exceeding 500 require a minimum of 3 exits. Spaces exceeding 1,000 require 4 exits.
📋 Code
IBC 1017.2 — Exit Access Travel Distance
Maximum travel distance from any point in a building to an exit shall not exceed 200 feet unsprinklered or 250 feet sprinklered for most occupancies. Specific occupancies have modified limits.
📋 Code
IBC Table 601 — Fire-Resistance Rating Requirements
Specifies minimum fire-resistance ratings for structural elements based on construction type (Type I through V). Type IA requires 3-hour rated structural frame, 2-hour floors, and 1.5-hour roof.