HomeKnowledgeIRC R311.7 — Stairways (Residential)
📋 CodecodesStairs

IRC R311.7 — Stairways (Residential)

Updated Mar 25, 2026
Residential stair requirements: minimum 36-inch width, maximum 7-3/4 inch riser, minimum 10-inch tread depth, maximum 3/8-inch variation between risers. Handrail required on at least one side, 34-38 inches high.

IRC stair requirements are among the most commonly cited violations in residential inspections. Width: minimum 36 inches clear above handrail, 31.5 inches at and below handrail height. Risers: maximum 7-3/4 inches, minimum 4 inches. Treads: minimum 10 inches depth. Nosing: 3/4 to 1-1/4 inches when tread depth is less than 11 inches. Uniformity: maximum 3/8-inch variation in riser height or tread depth in any flight. Headroom: minimum 6 feet 8 inches measured vertically from sloped plane of nosings. Handrail: required on at least one side, 34-38 inches measured from nosing. Graspable profile: 1-1/4 to 2-inch circular cross-section, or non-circular with perimeter 4 to 6-1/4 inches. Landing: at top and bottom, minimum 36 inches measured in direction of travel. Winders: allowed if tread at 12-inch walk line is minimum 10 inches, narrowest point minimum 6 inches. Spiral stairs: minimum 26-inch width, 7.5-inch tread at 12 inches from narrow edge. These dimensions must be verified at framing inspection.

TAGS
ircstairsrisertreadhandrailresidentialegressinspection
DETAILS
chapter
3 - Building Planning
severity
life_safety
code year
2024
code system
IRC
building types
["residential_single","townhouse"]
section number
R311.7
RELATED KNOWLEDGE
📋 Code
IBC 903.2.1 — Group A Occupancies (Sprinkler Requirements)
Automatic sprinkler system required throughout buildings with Group A occupancy where fire area exceeds 5,000 square feet, or overall building area exceeds 12,000 square feet, or occupant load of the fire area exceeds 300.
📋 Code
IBC 903.2.7 — Group M Occupancies (Retail Sprinkler Requirements)
Automatic sprinkler system required in Group M (mercantile) occupancies where fire area exceeds 12,000 square feet or building is more than three stories above grade.
📋 Code
IBC 903.2.11.3 — Buildings 55 Feet or More in Height
Automatic sprinkler system required throughout buildings with a floor level having an occupant load of 30 or more that is located 55 feet or more above the lowest level of fire department vehicle access.
📋 Code
IBC 1015.1 — Exit and Exit Access Doorways Required
Two exits or exit access doorways required from any space where occupant load exceeds the table values. Spaces with occupant load exceeding 500 require a minimum of 3 exits. Spaces exceeding 1,000 require 4 exits.
📋 Code
IBC 1017.2 — Exit Access Travel Distance
Maximum travel distance from any point in a building to an exit shall not exceed 200 feet unsprinklered or 250 feet sprinklered for most occupancies. Specific occupancies have modified limits.
📋 Code
IBC Table 601 — Fire-Resistance Rating Requirements
Specifies minimum fire-resistance ratings for structural elements based on construction type (Type I through V). Type IA requires 3-hour rated structural frame, 2-hour floors, and 1.5-hour roof.
← Back to Knowledge Garden