UK Building Regulations — Overview (Approved Documents A-S)

Updated Mar 25, 2026
England & Wales building regulations organized into Approved Documents covering structure, fire, ventilation, drainage, and more.

Building Regulations 2010 (as amended): Approved Documents provide practical guidance. Part A: Structure (loads, ground movement, disproportionate collapse). Part B: Fire Safety (means of warning/escape, fire spread, access for fire service) — B1 dwellings, B2 other buildings. Part C: Site Preparation/Resistance to Contaminants and Moisture. Part D: Toxic substances. Part E: Sound (walls STC 45, floors STC 45 + IIC 62 between dwellings). Part F: Ventilation (intermittent/continuous extract, background ventilation, whole-building). Part G: Sanitation/Hot Water/Water Efficiency (125 L/person/day). Part J: Combustion appliances. Part K: Protection from falling. Part L: Conservation of Fuel and Power (2021: U-values walls 0.18-0.26, roof 0.11-0.15, windows 1.2-1.4). Part M: Disability access (M4(1) visitable, M4(2) accessible, M4(3) wheelchair). Part O: Overheating (2022, new). Part S: EV Charging (2022, new). Building control: Local Authority or Approved Inspector.

TAGS
UKbuilding-regulationsapproved-documentsEnglandWales
DETAILS
country
UK
code system
UK Building Regulations 2010
RELATED KNOWLEDGE
📋 Code
IBC 903.2.1 — Group A Occupancies (Sprinkler Requirements)
Automatic sprinkler system required throughout buildings with Group A occupancy where fire area exceeds 5,000 square feet, or overall building area exceeds 12,000 square feet, or occupant load of the fire area exceeds 300.
📋 Code
IBC 903.2.7 — Group M Occupancies (Retail Sprinkler Requirements)
Automatic sprinkler system required in Group M (mercantile) occupancies where fire area exceeds 12,000 square feet or building is more than three stories above grade.
📋 Code
IBC 903.2.11.3 — Buildings 55 Feet or More in Height
Automatic sprinkler system required throughout buildings with a floor level having an occupant load of 30 or more that is located 55 feet or more above the lowest level of fire department vehicle access.
📋 Code
IBC 1015.1 — Exit and Exit Access Doorways Required
Two exits or exit access doorways required from any space where occupant load exceeds the table values. Spaces with occupant load exceeding 500 require a minimum of 3 exits. Spaces exceeding 1,000 require 4 exits.
📋 Code
IBC 1017.2 — Exit Access Travel Distance
Maximum travel distance from any point in a building to an exit shall not exceed 200 feet unsprinklered or 250 feet sprinklered for most occupancies. Specific occupancies have modified limits.
📋 Code
IBC Table 601 — Fire-Resistance Rating Requirements
Specifies minimum fire-resistance ratings for structural elements based on construction type (Type I through V). Type IA requires 3-hour rated structural frame, 2-hour floors, and 1.5-hour roof.