📋 Codeconstruction

IBC Section 1013 — Exit Signs

Updated Apr 3, 2026
Specifies illumination, color, size, and placement requirements for exit identification signage.

Section 1013 requires clearly visible and illuminated exit signs to identify exits throughout buildings. Exit signs must be red lettering on white background or white lettering on red background, with letter height minimum 6 inches. Exit signs must be illuminated with minimum 5-foot candles unless they are photoluminescent. Illuminated signs use either incandescent or LED light sources with integral batteries for operation during power loss. Exit signs must be visible from all directions with maximum 200 feet viewing distance. Directional arrows on exit signs indicate exit location when not obvious. Tactile signage (raised characters and Braille) is required at certain locations for persons with visual impairments. Exit signs must be maintained in functional condition with any damaged or non-functional signs replaced immediately.

TAGS
ibcchapter-10exit-signssignage
DETAILS
section
1013
category
Means of Egress
code body
IBC
code year
2021
RELATED KNOWLEDGE
📋 Code
IBC 903.2.1 — Group A Occupancies (Sprinkler Requirements)
Automatic sprinkler system required throughout buildings with Group A occupancy where fire area exceeds 5,000 square feet, or overall building area exceeds 12,000 square feet, or occupant load of the fire area exceeds 300.
📋 Code
IBC 903.2.7 — Group M Occupancies (Retail Sprinkler Requirements)
Automatic sprinkler system required in Group M (mercantile) occupancies where fire area exceeds 12,000 square feet or building is more than three stories above grade.
📋 Code
IBC 903.2.11.3 — Buildings 55 Feet or More in Height
Automatic sprinkler system required throughout buildings with a floor level having an occupant load of 30 or more that is located 55 feet or more above the lowest level of fire department vehicle access.
📋 Code
IBC 1015.1 — Exit and Exit Access Doorways Required
Two exits or exit access doorways required from any space where occupant load exceeds the table values. Spaces with occupant load exceeding 500 require a minimum of 3 exits. Spaces exceeding 1,000 require 4 exits.
📋 Code
IBC 1017.2 — Exit Access Travel Distance
Maximum travel distance from any point in a building to an exit shall not exceed 200 feet unsprinklered or 250 feet sprinklered for most occupancies. Specific occupancies have modified limits.
📋 Code
IBC Table 601 — Fire-Resistance Rating Requirements
Specifies minimum fire-resistance ratings for structural elements based on construction type (Type I through V). Type IA requires 3-hour rated structural frame, 2-hour floors, and 1.5-hour roof.