IBC Chapter 17 — Special Inspections and Tests

Updated Mar 25, 2026
Requirements for special inspections, contractor responsibilities, and structural testing during construction including concrete, steel, masonry, wood, and soils.

Section 1704: Required special inspections — statement of special inspections prepared by registered design professional. Section 1705.1: Concrete — continuous inspection during placement of reinforcement, prestressing, concrete placement. Batch plant inspection, cylinder testing per ACI 318. Section 1705.2: Steel — shop and field welding inspection per AWS D1.1, high-strength bolting verification, structural steel details. Section 1705.4: Masonry — continuous or periodic inspection per TMS 402. Grout placement, mortar proportions, reinforcement placement. Section 1705.5: Wood — prefabricated structural elements, metal plate connected trusses, high-load connections. Section 1705.6: Soils — fill placement, compaction, special grading, controlled fill, underpinning. Section 1705.12: Sprayed fire-resistant materials — density, thickness, bond strength. Section 1706: Special inspections for wind resistance — structural wood, cold-formed steel. Section 1707: Special inspections for seismic resistance — per ASCE 7, seismic force-resisting systems.

TAGS
IBCspecial-inspectionstructural-testingconcrete-testingsteel-weldingmasonry-inspection
DETAILS
code year
2024
code system
IBC
code section
Chapter 17
RELATED KNOWLEDGE
📋 Code
IBC 903.2.1 — Group A Occupancies (Sprinkler Requirements)
Automatic sprinkler system required throughout buildings with Group A occupancy where fire area exceeds 5,000 square feet, or overall building area exceeds 12,000 square feet, or occupant load of the fire area exceeds 300.
📋 Code
IBC 903.2.7 — Group M Occupancies (Retail Sprinkler Requirements)
Automatic sprinkler system required in Group M (mercantile) occupancies where fire area exceeds 12,000 square feet or building is more than three stories above grade.
📋 Code
IBC 903.2.11.3 — Buildings 55 Feet or More in Height
Automatic sprinkler system required throughout buildings with a floor level having an occupant load of 30 or more that is located 55 feet or more above the lowest level of fire department vehicle access.
📋 Code
IBC 1015.1 — Exit and Exit Access Doorways Required
Two exits or exit access doorways required from any space where occupant load exceeds the table values. Spaces with occupant load exceeding 500 require a minimum of 3 exits. Spaces exceeding 1,000 require 4 exits.
📋 Code
IBC 1017.2 — Exit Access Travel Distance
Maximum travel distance from any point in a building to an exit shall not exceed 200 feet unsprinklered or 250 feet sprinklered for most occupancies. Specific occupancies have modified limits.
📋 Code
IBC Table 601 — Fire-Resistance Rating Requirements
Specifies minimum fire-resistance ratings for structural elements based on construction type (Type I through V). Type IA requires 3-hour rated structural frame, 2-hour floors, and 1.5-hour roof.