IBC Chapter 4 — Special Detailed Requirements Based on Occupancy

Updated Mar 26, 2026
High-rise, atriums, underground, hospitals, detention, stages. Special fire/life safety provisions.

IBC Ch4: 403 high-rise (>75ft above FLED): sprinklered, Class I standpipe, fire alarm with voice, smokeproof enclosures, secondary water supply, emergency power. 404 atriums: sprinklered, smoke control, glass guards per 2406.2. 405 underground buildings (>30ft below exit): compartmented, standby power. 407 Group I-2 hospitals: corridor walls smoke partitions, smoke compartments 22,500sf max. 408 Group I-3 detention: smoke-proof locks, guard staff. 410 stages/platforms: proscenium wall 2-hr, fire curtain, sprinklers. 420 Group I-1/R-4 assisted living: fire barriers, smoke alarms.

TAGS
IBChigh-riseatriumhospitalundergrounddetention
DETAILS
code year
2024
code section
Chapter 4
RELATED KNOWLEDGE
📋 Code
IBC 903.2.1 — Group A Occupancies (Sprinkler Requirements)
Automatic sprinkler system required throughout buildings with Group A occupancy where fire area exceeds 5,000 square feet, or overall building area exceeds 12,000 square feet, or occupant load of the fire area exceeds 300.
📋 Code
IBC 903.2.7 — Group M Occupancies (Retail Sprinkler Requirements)
Automatic sprinkler system required in Group M (mercantile) occupancies where fire area exceeds 12,000 square feet or building is more than three stories above grade.
📋 Code
IBC 903.2.11.3 — Buildings 55 Feet or More in Height
Automatic sprinkler system required throughout buildings with a floor level having an occupant load of 30 or more that is located 55 feet or more above the lowest level of fire department vehicle access.
📋 Code
IBC 1015.1 — Exit and Exit Access Doorways Required
Two exits or exit access doorways required from any space where occupant load exceeds the table values. Spaces with occupant load exceeding 500 require a minimum of 3 exits. Spaces exceeding 1,000 require 4 exits.
📋 Code
IBC 1017.2 — Exit Access Travel Distance
Maximum travel distance from any point in a building to an exit shall not exceed 200 feet unsprinklered or 250 feet sprinklered for most occupancies. Specific occupancies have modified limits.
📋 Code
IBC Table 601 — Fire-Resistance Rating Requirements
Specifies minimum fire-resistance ratings for structural elements based on construction type (Type I through V). Type IA requires 3-hour rated structural frame, 2-hour floors, and 1.5-hour roof.