HomeKnowledgeIBC Chapter 4 — Special Detailed Requirements Based on Use and Occupancy
📋 Codecodesspecial-uses

IBC Chapter 4 — Special Detailed Requirements Based on Use and Occupancy

Updated Mar 25, 2026
Special requirements for atriums, covered/open malls, high-rise buildings, underground buildings, motor vehicle facilities, aircraft facilities, stages, and other specific uses.

Section 403: High-rise buildings — buildings with occupied floor >75 ft above lowest level of fire department access. Required: automatic sprinklers, fire alarm, emergency voice/alarm, fire command center, standby power, luminous egress path markings. Section 404: Atriums — require sprinklers, smoke control, glass/fire barriers. Section 402: Covered and open mall buildings — maximum 3 levels above grade, anchor buildings require fire barriers, exit travel distance limits. Section 406: Motor vehicle-related occupancies — parking garages open/enclosed, repair garages, motor fuel-dispensing facilities. Section 410: Stages and platforms — proscenium walls, standpipe/sprinkler, smoke control for stages over 1,000 sf.

TAGS
IBChigh-riseatriummallparking-garagestage
DETAILS
code year
2024
code system
IBC
code section
Chapter 4
RELATED KNOWLEDGE
📋 Code
IBC 903.2.1 — Group A Occupancies (Sprinkler Requirements)
Automatic sprinkler system required throughout buildings with Group A occupancy where fire area exceeds 5,000 square feet, or overall building area exceeds 12,000 square feet, or occupant load of the fire area exceeds 300.
📋 Code
IBC 903.2.7 — Group M Occupancies (Retail Sprinkler Requirements)
Automatic sprinkler system required in Group M (mercantile) occupancies where fire area exceeds 12,000 square feet or building is more than three stories above grade.
📋 Code
IBC 903.2.11.3 — Buildings 55 Feet or More in Height
Automatic sprinkler system required throughout buildings with a floor level having an occupant load of 30 or more that is located 55 feet or more above the lowest level of fire department vehicle access.
📋 Code
IBC 1015.1 — Exit and Exit Access Doorways Required
Two exits or exit access doorways required from any space where occupant load exceeds the table values. Spaces with occupant load exceeding 500 require a minimum of 3 exits. Spaces exceeding 1,000 require 4 exits.
📋 Code
IBC 1017.2 — Exit Access Travel Distance
Maximum travel distance from any point in a building to an exit shall not exceed 200 feet unsprinklered or 250 feet sprinklered for most occupancies. Specific occupancies have modified limits.
📋 Code
IBC Table 601 — Fire-Resistance Rating Requirements
Specifies minimum fire-resistance ratings for structural elements based on construction type (Type I through V). Type IA requires 3-hour rated structural frame, 2-hour floors, and 1.5-hour roof.