HomeKnowledgeIECC Windows and Doors Performance
📋 Codeconstruction

IECC Windows and Doors Performance

Updated Apr 3, 2026
Establishes U-factor and solar heat gain requirements for windows, skylights, and doors.

IECC Section 5 addresses window and door thermal performance. Windows must meet U-factor (heat transfer rate) limits ranging from 0.23-0.62 depending on climate zone and window type. Solar Heat Gain Coefficient (SHGC) limits of 0.25-0.45 reduce cooling loads in sunny climates. Skylights must meet stricter U-factor requirements than vertical windows due to roof exposure. French doors and sliding glass doors must meet door U-factor requirements. Operable windows and doors that are properly installed and maintained provide better performance than air leakage paths.

TAGS
ieccenergy-codewindowsdoors
DETAILS
section
502
category
Envelope Requirements
code body
IECC
code year
2021
RELATED KNOWLEDGE
📋 Code
IBC 903.2.1 — Group A Occupancies (Sprinkler Requirements)
Automatic sprinkler system required throughout buildings with Group A occupancy where fire area exceeds 5,000 square feet, or overall building area exceeds 12,000 square feet, or occupant load of the fire area exceeds 300.
📋 Code
IBC 903.2.7 — Group M Occupancies (Retail Sprinkler Requirements)
Automatic sprinkler system required in Group M (mercantile) occupancies where fire area exceeds 12,000 square feet or building is more than three stories above grade.
📋 Code
IBC 903.2.11.3 — Buildings 55 Feet or More in Height
Automatic sprinkler system required throughout buildings with a floor level having an occupant load of 30 or more that is located 55 feet or more above the lowest level of fire department vehicle access.
📋 Code
IBC 1015.1 — Exit and Exit Access Doorways Required
Two exits or exit access doorways required from any space where occupant load exceeds the table values. Spaces with occupant load exceeding 500 require a minimum of 3 exits. Spaces exceeding 1,000 require 4 exits.
📋 Code
IBC 1017.2 — Exit Access Travel Distance
Maximum travel distance from any point in a building to an exit shall not exceed 200 feet unsprinklered or 250 feet sprinklered for most occupancies. Specific occupancies have modified limits.
📋 Code
IBC Table 601 — Fire-Resistance Rating Requirements
Specifies minimum fire-resistance ratings for structural elements based on construction type (Type I through V). Type IA requires 3-hour rated structural frame, 2-hour floors, and 1.5-hour roof.