HomeKnowledgeIRC R311 — Means of Egress
📋 Codecodesegress

IRC R311 — Means of Egress

Updated Mar 25, 2026
Residential egress requirements: exterior exit doors, hallways, stairways, ramps, handrails, guards, and emergency escape openings.

Section R311.2: Exit door — at least one exit door, min 32 in clear width, max 36 in landing to grade. Section R311.3: Floors and landings — landing at each door min 36 in in direction of travel, max 1.5 in threshold height. Section R311.4: Hallways — min 36 in width. Section R311.7: Stairways — min 36 in width, max riser 7.75 in, min tread 10 in, max 4-3/8 in rise nosing radius. Handrails: 34-38 in height, graspable profile 1.25-2 in. Guards: min 36 in height at stairs, 36 in at other locations. Section R311.7.5: Stairway headroom — min 6 ft 8 in. Section R310: Emergency escape and rescue openings — every sleeping room and basement habitable room. Min 5.7 sf net clear, min 20 in wide, min 24 in high. Sill height max 44 in above floor. Window wells for below-grade: min 9 sf, 36 in horizontal projection.

TAGS
IRCresidentialegressstairwayhandrailguardemergency-escape
DETAILS
code year
2024
code system
IRC
code section
R311
RELATED KNOWLEDGE
📋 Code
IBC 903.2.1 — Group A Occupancies (Sprinkler Requirements)
Automatic sprinkler system required throughout buildings with Group A occupancy where fire area exceeds 5,000 square feet, or overall building area exceeds 12,000 square feet, or occupant load of the fire area exceeds 300.
📋 Code
IBC 903.2.7 — Group M Occupancies (Retail Sprinkler Requirements)
Automatic sprinkler system required in Group M (mercantile) occupancies where fire area exceeds 12,000 square feet or building is more than three stories above grade.
📋 Code
IBC 903.2.11.3 — Buildings 55 Feet or More in Height
Automatic sprinkler system required throughout buildings with a floor level having an occupant load of 30 or more that is located 55 feet or more above the lowest level of fire department vehicle access.
📋 Code
IBC 1015.1 — Exit and Exit Access Doorways Required
Two exits or exit access doorways required from any space where occupant load exceeds the table values. Spaces with occupant load exceeding 500 require a minimum of 3 exits. Spaces exceeding 1,000 require 4 exits.
📋 Code
IBC 1017.2 — Exit Access Travel Distance
Maximum travel distance from any point in a building to an exit shall not exceed 200 feet unsprinklered or 250 feet sprinklered for most occupancies. Specific occupancies have modified limits.
📋 Code
IBC Table 601 — Fire-Resistance Rating Requirements
Specifies minimum fire-resistance ratings for structural elements based on construction type (Type I through V). Type IA requires 3-hour rated structural frame, 2-hour floors, and 1.5-hour roof.